PLANE funct.: MOVE not possible
Cause of error
In the PLANE AXIS function, you programmed 3 rotary axes with the MOVE option.
In this case the TNC would have to move 6 axes at the same time, but it cannot interpolate more than 5 axes.
Error correction
- Use the TURN positioning behavior
- In the next block, use the STAY positioning behavior and move the rotary axes to LA A+Q120 B+Q121 C+Q122