Error message
DCM: Status settings incorrect
Cause of error
The machine parameter MP7300 is set so that the TNC deletes the tool data at program end. Then collision-protected traversing is no longer possible.
Error correction
Set MP7300 so that the TNC does not reset the tool status at program end. Then conduct a TOOL CALL so that the compensation values are active.