Error message
E210 Timeout during stopping %.2s
Cause of error
- The maximum permissible time for stopping a motor was exceeded
Error correction
- Check the safe machine parameters:
MP523: Duration of controlled stopping for axes
MP524: Duration of controlled stopping for spindle
- Inform your service agency.