Reactions:
Remedy:
Program Continuation:
Hardware plug-in module for communication with the digitizer missing
MD $MN_ASSIGN_DIGITIZE_TO_CHAN was used to activate the digitizing function by assigning it to a channel. The function requires a hardware module (RS422 board plugged into the NCU) for communication with the digitizing unit. This module was not found when booting.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Plug in communications module or cancel channel assignment.
Switch control OFF - ON.