4013

Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


Invalid NCU link configuration by machine data %1 = %2 , on NCU_1 = %3

%1 = String: MD identifier

%2 = Index: MD array

%3 = MD value of master NCU

The link module configuration detected on the local NCU is different from the master NCU of the NCU cluster. The link module configuration defines the system clock time, the communication baudrate and the maximum number of message transfer retries.

The following machine data are used for this purpose: SYSCLOCK_SAMPL_TIME_RATIO,

IPO_SYSCLOCK_TIME_RATIO,

LINK_RETRY_CTR,

LINK_BAUDRATE_SWITCH,

SYSCLOCK_CYCLE_TIME

The values of these machine data must be the same on all NCUs.

-    NC not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

The machine data required for the link module configuration must be the same on all NCUs in the cluster.

Switch control OFF - ON.


1-51


© Siemens AG 2005 All Rights Reserved