4021

Channel %1 identifier %2 used several times in machine data %3

Parameters:

%1 = Channel number

Definitions:

%2 = String: Name of identifier %3 = String: MD identifier

To determine the name in the channel-specific tables for geometry axes and channel axes an identifier already existing in the control has been used.

Reactions:

-    NC not ready.

-    Mode group not ready, also effective for single axes

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Select for the identifier to be entered a character string that is not yet used in the system (max. 32 characters).

Program Continuation:

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved