4035

Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


Interpolation cycle from NCU%1 = %2 does not match NCU%3 = %4

%1 = NCU_number1

%2 = MD value of NCU_number1

%3 = NCU_number2 (with slowest IPO cycle)

%4 = MD value of NCU_number2

Occurs only with an NCU link system. The interpolation cycles of the NCUs specified in the alarm do not match one another. The slowest IPO cycle in interconnected NCU systems must be an integral multiple of all configured IPO cycles.

-    NC not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Set a suitable value in MN_IPO_SYSCLOCK_TIME_RATIO for all interconnected NCUs. Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved


1-72