4076

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

%1 Machine data could not be changed with permission level %2

%1 = Number of MDs

%2 = Preset access authorization

On executing a TOA file or when writing data from the part program an attempt has been made to write data with a higher protection level than the access authorization currently set in the control. The data in question have not been written and program execution is continued without hindrance. This alarm is issued on acknowledging the alarm EXBSAL_MD_PERMISSION_DENIED. It can be cleared only with Power On.

-    NC Start disable in this channel.

-    Alarm display.

Please inform the authorized personnel/service department. Set the required access level by means of keyswitch or password entry or delete the machine data concerned from the MD file/part program.

Switch control OFF - ON.

1-85

© Siemens AG 2005 All Rights Reserved