4170

Definitions:


Reactions:


Remedy:

Program Continuation:


Invalid M function number for channel synchronisation assigned

An M number between 0 and 99 has been specified In machine data $MN_EXTERN_CHAN_SYNC_M_NR_MIN or

$MN_EXTERN_CHAN_SYNC_M_NR_MAX for the configuration of the M number range for channel synchronization in ISO2/3 mode or the machine data $MN_EXTERN_CHAN_SYNC_M_NR_MAX is smaller than $MN_EXTER N_CHAN_SYNC_M_NR_MIN.

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Check machine data $MN_EXTERN_CHAN_SYNC_M_NR_MIN and $MN_EXTER N_CHAN_SYNC_M_NR_MAX.

Switch control OFF - ON.


1-101