4180

Invalid M function number assigned to enable ASUP

Definitions:

An invalid M function number has been assigned for activation of ASUP. An illegal M number has been assigned in machine data $MN_EXTERN_M_NO_SET_INT or $MN_EXTERN_M_NO_DISABLE_INT for the configuration of the M number range for activation/deactivation of the interrupt program.

Reactions:

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Check machine data $MN EXTERN M NO SET INT and $MN_EXTERN_M_NO_DISABLE_INT.

Program Continuation:

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved

1-102