4280

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Assignment of NCK input/output byte via MD %1[%2] does not match hardware configuration

%1 = String: MD identifier %2 = Index: MD array

When booting, the required input/output module was not found at the slot specified in the MD.

-    NC not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Check hardware and correct the MD if necessary. Note: Monitoring of the hardware configuration is performed independently of the number of activated inputs/outputs (MD 10300 - 10360 FASTIO_ANA(DIG)_NUM_INPUTS(OUTPUTS))

Switch control OFF - ON.

1-121

© Siemens AG 2005 All Rights Reserved