Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 block %2 no data set available for transformation no. %3
%1 = Channel number %2 = Block number, label %3 = Transformation number
Only a limited number of machine data sets (usually 2) is available for each related group of transformations (e.g. orientation transformations, Transmit, Tracyl, etc.). This alarm is output if an attempt is made to set more transformations from a group.
Example:
Two orientation transformations are allowed. The machine data contains e.g.: TRAFO_TYPE_1 = 16 ; 1st orientation transformation TRAFO_TYPE_2 = 33 ; 2nd orientation transformation TRAFO_TYPE_3 = 256 ; 1st transmit transformation
TRAFO_TYPE_4 = 20 ; 3rd orientation transformation ==> This entry triggers alarm
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Enter valid machine data.
Clear alarm with the RESET key. Restart part program