6453


Parameters:


Definitions:

Reactions:


Remedy:


Program Continuation:


Channel %1 block %2 tool change not possible. No assignment between toolholder/spindle no. = %3 and buffer magazine location %4

%1 = Channel ID

%2 = Block number, label

%3 = Spindle no.

%4 = Location no.

The desired tool change is not possible. No relation has been defined between the toolholder/spindle number and the buffer magazine location (Location No.)

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Check whether the magazine data ($TC_MLSR) have been defined correctly.

Check whether the alarm-causing program command _ e.g. TCI _ has been programmed correctly.

Clear alarm with NC START or RESET key and continue the program.


1-183