8034

Option 'activation of axis containers' not set

Definitions:

The option for activating the axis container function in MD $MN_AXCONF_LOGIC_MACHAX_TAB is not enabled.

Reactions:

-    Interpreter stop

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

Buy option

Do not configure any containers

Program Continuation:

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-230