8041

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1: MD %2 reset, corresponding option not sufficient

%1 = Axis number %2 = String: MD identifier

All of the axes selected in the machine data of the assigned option are used. Safety functions have been selected for too many axes in the axial machine data.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Switch control OFF - ON.


1-235