Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 axis %2 rests on software limit switch %3
%1 = Channel number
%2 = Axis name, spindle number
%3 = String
The specified axis is already stationary at the displayed software limit.
- Alarm display.
Please inform the authorized personnel/service department. Machine data 36110 POS_LIMIT_PLUS/36130 POS_LIMIT_PLUS2 and 36100 POS_LIMIT_MINUS/36120 POS_LIMIT_MINUS2 must be checked for the software limit switches.
Shut down in JOG mode from the software limit switch.
Please inform the authorized personnel/service department.
Machine data:
Check the axis-specific interface signals: "2. "2nd software limit switch plus" (DB 31 - 61, DBX 12.3) or "2nd software limit switch minus" (DB 31 - 61, DBX 12.2) check whether the 2nd software limit switch is selected.
Alarm display showing cause of alarm disappears. No further operator action necessary.
© Siemens AG 2005 All Rights Reserved