10650

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 axis %2 incorrect gantry machine data, error code %3

%1 = Channel number %2 = Axis %3 = Error no.

An incorrect value was entered in the gantry-specific axial machine data. Further information can be derived from the error number.

Error no. = 1 => either an incorrect gantry unit has been entered or the designation of the following axis is incorrect.

Error no. = 2 => master axis has been specified more than once.

-    NC not ready.

-    Mode group not ready, also effective for single axes

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Correct the machine data: MD 37100 GANTRY_AXIS_TYPE

0: No gantry axis 1: Master axis grouping 1 11: Slave axis grouping 1 2: Master axis grouping 2 12: Slave axis grouping 2 3: Master axis grouping 3 13: Slave axis grouping 3 Switch control OFF - ON.


1-295