10704 |
Channel %1 block %2 protection zone monitoring is not guaranteed |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
New movements of a geometry axis which have been added could not be allowed for at the time of block preparation. It is therefore not certain that the protection zones will not be violated. This is just a warning message without further reactions. |
Reactions: |
- Interface signals are set. - Alarm display. |
Remedy: |
Take other measures to ensure that the geomotry axes motion, including the additional motion, does not violate the protection zones. (The warning comes nevertheless) or exclude additional motions. |
Program Continuation: |
Alarm display showing cause of alarm disappears. No further operator action necessary. |
© Siemens AG 2005 All Rights Reserved