10730

Channel %1 block %3 axis %2 working area limitation %4

Parameters:

%1 = Channel number

%2 = Axis name, spindle number

%3 = Block number, label

Definitions:

%4 = String ( + or - )

This alarm is generated if it is determined during block preparation that the programmed path of the axis will result in exceeding the working area limitation.

Reactions:

-    Correction block is reorganized.

-    Local alarm reaction.

Remedy:

-    Interface signals are set.

-    Alarm display.

a)    Check NC program for correct positional data and, if necessary, make corrections.

b)    Check zero offsets (current frame)

c)    Correct working area limitation via G25, or

d)    Correct working area limitation via setting data, or

e)    Deactivate working area limitation via setting data 43410 WORKAREA_MINUS_ENABLE=FALSE

Program Continuation:

Clear alarm with NC START or RESET key and continue the program.

© Siemens AG 2005 All Rights Reserved

1-314