10731

Parameters:


Definitions:

Reactions:


Remedy:

Program Continuation:


Channel %1 block %3 axis %2 working area limitation %4

%1 = Channel number %2 = Axis name, spindle number %3 = Block number, label %4 = String ( + or - )

For the axis, the planned motion violates the working area limit. The alarm is activated during the preparation of approach or rest blocks at REPOS.

-    Local alarm reaction.

-    Interface signals are set.

-    Alarm display.

Abort part program with reset.

Clear alarm with the RESET key. Restart part program


1-315


© Siemens AG 2005 All Rights Reserved