10744

Channel %1 block %2 no valid WAB direction defined

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

The tangent direction for smooth approach or retraction is not defined.

Possible causes:

Reactions:

In the program, no block with travel information follows the approach block.

Before a retraction block, no block with travel information has been programmed in a program.

The tangent to be used for WAB motion is vertical to the current machining plane.

-    Correction block is reorganized.

-    Local alarm reaction.

Remedy:

Program Continuation:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm at block end.

Modify part program.

Clear alarm with NC START or RESET key and continue the program.

© Siemens AG 2005 All Rights Reserved

1-320