10777

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 block %2 tool radius compensation: too many blocks with suppression of compensation

%1 = Channel number %2 = Block number, label

The maximum permissible number of blocks with active compensation suppression with tool radius compensation is limited by the machine data CUTCOM_MAXNUM_SUPPR_BLOCKS.

-    Correction block is reorganized.

-    Local alarm reaction.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm at block end.

Modify part program.

Modify machine data.

Check whether SBL2 is activated. With SBL2, a block is generated from each part program line which can lead to exceeding the maximum permissible number of empty blocks between two traversing blocks.

Clear alarm with NC START or RESET key and continue the program.

1-352