10880

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 block %2 too many empty blocks between two traversing blocks when inserting chamfers or radii

%1 = Channel number %2 = Block number, label

Between 2 blocks containing contour elements and which are to be joined with a chamfer or a radius (CHF, RND), more blocks without contour information have been programmed than provided for in the machine data 20200 CHFRND_MAXNUM_DUMMY_BLOCKS.

-    Correction block is reorganized.

-    Local alarm reaction.

-    Interface signals are set.

-    Alarm display.

Please inform the authorized personnel/service department. Modify the part program in order that the permissible number of dummy blocks is not exceeded or adapt the channel-specific machine data 20200 CHFRND_MAXNUM_DUMMY_BLOCKS (dummy blocks with chamfers/radii) to the maximum number of dummy blocks.

Clear alarm with NC START or RESET key and continue the program.

1-374