12030

Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 invalid parameter or data type in %3

%1 = Channel number %2 = Block number, label %3 = Source string

In polynomial interpolation, polynomials must not be greater than the 3rd degree (refer to

Programming Guide).

f(p) = a0 + a1 p + a2 p2 + a3 p3

The coefficients a0 (the starting points) are identical to the end points of the preceding block and need not be programmed. In the polynomial block, a maximum of 3 coefficients per axis is therefore allowed (a1, a2, a3).

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block.

Clear alarm with NC START or RESET key and continue the program.


1-413


© Siemens AG 2005 All Rights Reserved