12050

Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 DIN address %3 not configured

%1 = Channel number

%2 = Block number, label

%3 = DIN address in the source text block

The name of the DIN address (e.g. X, U, X1) is not defined in the control. In addition to the fixed DIN addresses, the control also has variable addresses. Refer to "Variable addresses" in the Programming Guide. The names of these addresses can be altered by machine data.

e.g.: DIN identifier -> Configured identifier G01 -> LINE, G04 -> WAIT ...

-    Correction block

-    Interface signals are set.

-    Alarm display.

Study the Programming Guide and the machine data with respect to the addresses actually configured and their significance and correct the DIN block accordingly.

Clear alarm with NC START or RESET key and continue the program.


1-415


© Siemens AG 2005 All Rights Reserved