12110

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 block %2 block syntax cannot be interpreted

%1 = Channel number %2 = Block number, label

The addresses programmed in the block are not permissible together with the valid syntax defining G function, e.g. G1 I10 X20 Y30 F1000.

An interpolation parameter must not be programmed in the linear block.

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block.

Check the block structure and correct in accordance with the programming requirements. Clear alarm with NC START or RESET key and continue the program.


1-421


© Siemens AG 2005 All Rights Reserved