12120

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 G function not separately programmed

%1 = Channel number %2 = Block number, label

The G function programmed in this block must be alone in the block. No general

addresses or synchronous actions may occur in the same block. These G functions are:

G25, G26: Working area and spindle speed limitation

G110, G111, G112: Pole programming with polar coordinates

G92: Spindle speed limitation with v constant

STARTFIFO, STOPFIFO: Control of preprocessing buffer

E.g. G4 F1000 M100: no M function allowed in the G4 block.

-    Correction block

-    Interface signals are set.

-    Alarm display.

Program G function by itself in the block.

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved