Channel %1 block %2 number of parameters too high %3

%1 = Channel number %2 = Block number, label %3 = Source string

When calling a function or a procedure (predefined or user-defined) more parameters were transferred than defined.

Predefined functions and procedures: The number of parameters has been set permanently in the NCK.

User-defined functions and procedures: The number of parameters is established by type and name in the definition.

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block. Check whether the correct procedure/function has been called. Program the number of parameters in accordance with the procedure/function.

Clear alarm with NC START or RESET key and continue the program.