12530

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 block %2 invalid index for %3

%1 = Channel number %2 = Block number, label %3 = Source string

In macro definitions, an attempt was made to define a G function with more than 3 decades or an M function with more than 2 decades as identifier of the macro. Example:

_N_UMAC_DEF DEFINE G4444 AS G01 G91 G1234 DEFINE M333 AS M03 M50 M99

M17

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block. Modify the macro definition in accordance with the Programming Guide.

Clear alarm with NC START or RESET key and continue the program.


1-465