12550

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 block %2 name %3 not defined or option not installed

%1 = Channel number %2 = Block number, label %3 = Source symbol

The identifier displayed has not been defined before being used.

Macro: The keyword, to be defined with the DEFINE ... AS ... statement, is missing in one file:

_N_SMAC_DEF

_N_MMAC_DEF

_N_UMAC_DEF

_N_SGUD_DEF

_N_MGUD_DEF

_N_UGUD_DEF

Variable: DEF statement is missing Program: PROC declaration is missing

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block.

Correct the name used (writing error)

Check definitions of variables, subroutines and macros Declare subroutine with EXTERN, load subroutine to SPF-Dir Check interface definition of subroutine Check options

Clear alarm with NC START or RESET key and continue the program.


1-467


© Siemens AG 2005 All Rights Reserved