12560

Channel %1 block %2 programmed value %3 exceeds allowed limits

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

Reactions:

%3 = Source string

In a value assignment, the permissible value range of the data type has been exceeded.

- Correction block

Remedy:

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block.

Assign value within the value range of the various data types, or if necessary use another type in order to increase the size of the value range, e.g. INT ->REAL.

Value ranges of the various variable types:

REAL: Property: Fractional number with dec. pt., value range: +/-(2-1022-2+1023)

INT: Property: Integers with signs, value range: +/-(231-1)

BOOL: Property: Truth value TRUE, FALSE, value range: 0,1

CHAR: Property: 1 ASCII character, value range: 0-255

STRING: Property: Character string (max. 100 values), value range: 0-255

AXIS: Property: Axis addresses, value range: Axis names only

FRAME: Property: Geometric information, value range: As for axis paths

Program Continuation:

Clear alarm with NC START or RESET key and continue the program.

© Siemens AG 2005 All Rights Reserved

1-472