14033
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 block %2 involute: no end point programmed
%1 = Channel number %2 = Block number, label
No end point was programmed for the involute. This is either possible via direct programming with the geometry axis identifiers or by specifying the angle between start and end vector.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
1-524