Reactions:
Remedy:
Program Continuation:
Channel %1 block %2 invalid D number
%1 = Channel number %2 = Block number, label
A value less than zero has been programmed under address D.
A set of parameters with 25 correction values has been automatically assigned to each active tool. Each tool can have 9 sets of parameters (D1 - D9, initial setting is D1). When the D number changes, the new parameter set is active (D0 is used for deselecting the correction values).
N10 G.. X... Y... T15 ; Parameter set D1 of T15 active N50 G.. X... D3 M.. ; Parameter set D3 of T15 active
N60 G.. X.. T20 ; Parameter set D1 of T20 active
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Program D numbers in the permissible value range (D0, D1 to D9).
Clear alarm with NC START or RESET key and continue the program.