14090

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 invalid D number

%1 = Channel number %2 = Block number, label

A value less than zero has been programmed under address D.

A set of parameters with 25 correction values has been automatically assigned to each active tool. Each tool can have 9 sets of parameters (D1 - D9, initial setting is D1). When the D number changes, the new parameter set is active (D0 is used for deselecting the correction values).

N10 G.. X... Y... T15 ; Parameter set D1 of T15 active N50 G.. X... D3 M..    ; Parameter set D3 of T15 active

N60 G.. X.. T20    ; Parameter set D1 of T20 active

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Program D numbers in the permissible value range (D0, D1 to D9).

Clear alarm with NC START or RESET key and continue the program.


1-543


© Siemens AG 2005 All Rights Reserved