14250

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 block %2 negative pole radius

%1 = Channel number %2 = Block number, label

In redefining the pole with G110, G111 or G112 in polar coordinates, the pole radius specified under keyword RP=... is negative. Only positive absolute values are permitted. Definition of terms:

Specification of end of block point with polar angle and polar radius, referring to the current pole (preparatory functions: G00/G01/G02/G03).

New definition of the pole with polar angle and pole radius, referring to the reference point selected with the G function. G110 ... last programmed point in the plane, G111 ... zero point of the current work, G112 ... last pole

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Correct the NC part program. Permissible inputs for the pole radius are only positive, absolute values that specify the distance between the reference point and the new pole. (The direction is defined with the pole angle AP=...).

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved


1-612