14763

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 too many link variables programmed

%1 = Channel number %2 = Block number, label

The number of NCU link variables programmed exceeds the maximum limit. The number is defined in MD $MC_MM_NUM_LINKVAR_ELEMENTS.

-    Interpreter stop

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Modify part program or machine data.

Clear alarm with the RESET key. Restart part program


© Siemens AG 2005 All Rights Reserved


1-680