Channel %1 block %2 error in selection or deselection of GWPS

%1 = Channel number %2 = Block number, label

On selecting GWPS programming (constant grinding wheel surface speed) with GWPSON, one of the following errors occurred:

An attempt has been made to select the GWPS programming for a spindle that has already been assigned to another tool by TMON, GWPSON, CLGON or activation of the tool length compensation.

An attempt has been made to select a tool which has not been defined.

An attempt has been made to select an edge (implicitely) which has not been defined (implicit selection: D1 of a tool, if no tool has been specified.)

Selection does not refer to a grinding-specific tool (400-499).

An attempt has been made to select GWPS for the active tool, although the TLC is not switched on.

Selection refers to an invalid spindle number.

A grinding wheel radius equal to zero has been specified.

On deselecting GWPS programming with GWPSOFF, one of the following errors occurred:

Deselection does not refer to a grinding-specific tool (400-499).

An attempt has been made to deselect GWPS for the active tool, although the tool length compensation has not been activated.

Deselection refers to an invalid spindle number.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Check GWPSON and GWPSOF command.

Check tool compensation data:

$TC_DP1 : 400 - 499;

$TC_TGP1: Spindle number.

Clear alarm with NC START or RESET key and continue the program.