15030

Channel %1 block %2 different measurement system settings

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

The INCH or METRIC instruction describes the system of measurement in which the data blocks have been read from the control. In order to prevent the incorrect interpretation of data intended for a particular system of measurement, a data block is only accepted if the above instruction matches the active system of measurement.

Reactions:

-    Interpreter stop

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

Change the system of measurement or load a data block which matches the system of measurement.

Program Continuation:

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-710