Program Continuation:
Channel %1 block %2 invalid block search command
%1 = Channel number %2 = Block number, label
The block search command (type of search target) is smaller than 1 or greater than 5. It is entered in column type of the block search window. The following block search orders are allowed.
Type Meaning
1 Search for block number
2 Search for label
3 Search for string
4 Search for program name
5 Search for line number in a file - Alarm display.
Modify the block search command.
Clear alarm with the Delete key or NC START.
© Siemens AG 2005 All Rights Reserved