15320

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 block %2 invalid block search command

%1 = Channel number %2 = Block number, label

The block search command (type of search target) is smaller than 1 or greater than 5. It is entered in column type of the block search window. The following block search orders are allowed.

Type Meaning

1    Search for block number

2    Search for label

3    Search for string

4    Search for program name

5    Search for line number in a file - Alarm display.

Modify the block search command.

Clear alarm with the Delete key or NC START.


1-731


© Siemens AG 2005 All Rights Reserved