15410

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 block %2 initialization file contains invalid M function

%1 = Channel number %2 = Block number, label

The only M function allowed in an Init block is the M02, M17 or M30 end-of-program function.

-    Interpreter stop

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

Remove all M functions from the Init block except for the end identifier.

An Init block may contain value assignments only (and global data definitions if they are not defined again in a program that can be executed later) but no motion or synchronous actions.

Clear alarm with the RESET key. Restart part program

1-741