Remedy:
Program Continuation:
Channel %1 block %2 machining stop after lift fast
%1 = Channel number %2 = Block number, label
LIFTFAST without interrupt routine (Asup) has been programmed. The channel is stopped after the lift motion has been carried out.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
After the channel stop, the axes must be retracted manually in JOG and the program aborted with Reset.
Clear alarm with the RESET key. Restart part program
© Siemens AG 2005 All Rights Reserved