Reactions:
Remedy:
Program Continuation:
Channel %1 block %2 no facing axis available
%1 = Channel number %2 = Block number, label
Diameter programming has been activated with the keyword DIAMON although no facing axis has been programmed in this NC block.
If the diameter axis is not a geometry axis, in the initial setting "DIAMON" the alarm appears as soon as the control is switched on.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Activate the modal G function DIAMON only in NC blocks containing a facing axis or deactivate diameter program with DIAMOF.
In machine data 20150 GCODE_RESET_VALUES[28] select "DIAMOF" for the initial setting.
Clear alarm with NC START or RESET key and continue the program.
© Siemens AG 2005 All Rights Reserved