16740

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 no geometry axis programmed

%1 = Channel number %2 = Block number, label

No geometry axis was programmed for tapping (G33) or for rigid tapping (G331, G332). The geometry axis is, however, essential if an interpolation parameter has been specified. Example:

N100 G33 Z400 K2 ; thread lead 2mm, thread end Z=400 mm N200 SPOS=0 ; position spindle in axis mode N201 G90 G331 Z-50 K-2 ; tapping to Z=-50, counterclockwise N202 G332 Z5 ; retraction, direction reversal automatic N203 S500 M03 ; spindle again in spindle mode

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Specify geometry axis and corresponding interpolation parameters.

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved


1-788