16770

Channel %1 block %2 axis %3 no measuring system available

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

%3 = Axis name, spindle number

SPCON, SPOS or SPOSA has been programmed. These functions require at least one measuring system. According to MD: NUM_ENCS the machine axis/spindle has no measuring system.

Reactions:

-    Interpreter stop

-    NC Start disable in this channel.

Remedy:

Program Continuation:

-    Interface signals are set.

-    Alarm display.

Please inform the authorized personnel/service department. Retrofit a measuring system. Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-798