16770 |
Channel %1 block %2 axis %3 no measuring system available |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
%3 = Axis name, spindle number SPCON, SPOS or SPOSA has been programmed. These functions require at least one measuring system. According to MD: NUM_ENCS the machine axis/spindle has no measuring system. |
Reactions: |
- Interpreter stop - NC Start disable in this channel. |
Remedy: Program Continuation: |
- Interface signals are set. - Alarm display. Please inform the authorized personnel/service department. Retrofit a measuring system. Clear alarm with the RESET key. Restart part program |
© Siemens AG 2005 All Rights Reserved