17150

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 block %2 maximum of %3 NCK outputs programmable in the block

%1 = Channel number %2 = Block number, label %3 = Quantity

No more than the specified number of outputs may be programmed in an NC block.

The quantity of hardware outputs is defined in the MDs:

10360 FASTIO_DIG_NUM_OUTPUTS and 10310 FASTIO_ANA_NUM_OUTPUTS

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Program fewer digital/analog outputs in a block. The specified maximum number applies in each case separately for analog or digital outputs. If necessary, program two NC blocks.

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved


1-902