17900

Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 axis %3 is no machine axis

%1 = Channel number

%2 = Block number, label

%3 = Axis name, spindle number

At this point, the block context calls for a machine axis. This is the case with:

G74 (reference point approach)

G75 (fixed point approach)

If a geometry or additional axis identifier is used, then it must also be allowed as machine axis identifier (MD 10000 AXCONF_MACHAX_NAME_TAB).

-    Interpreter stop

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

Use machine axis identifier when programming.

Clear alarm with the RESET key. Restart part program


1-943


© Siemens AG 2005 All Rights Reserved