18201 |
Channel %1 block %2 curve table: table %3 does not exist |
Parameters: |
%1 = Channel number %2 = Block number, label %3 = Number of curve table |
Definitions: |
An attempt was made to use a curve table whose table number is not known in the system \par. |
Reactions: |
- Interpreter stop - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. Change the table number in the program instruction or define the curve table with the desired table number. |
Program Continuation: |
Clear alarm with the RESET key. Restart part program |
© Siemens AG 2005 All Rights Reserved