20091

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 has not reached fixed stop

%1 = Axis name, spindle number

On attempting to traverse against a fixed stop, the programmed end position has been reached or the traversing movement has been aborted. The alarm can be concealed by means of the machine data $MA_FIXED_STOP_ALARM_MASK.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Correct the part program and the settings:

Has the traversing block been aborted?

If the axis position does not correspond to the programmed end position, then correct the end position.

If the programmed end position is in the part, the triggering criterion must be checked. Has the contour deviation leading to triggering been dimensioned too large? Has the torque limit been set too high?

Clear alarm with the RESET key in all channels of this mode group. Restart part program.


1-1005