20096

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Axis %1 brake test aborted, additional information %2

%1 = Axis name, spindle number

%2 = Error information based on $VA_FXS_INFO

The brake test has detected a problem. The additional info provides more detailed information on the cause of the alarm. The explanation can be found in the $VA_FXS_INFO system variable documentation.

Additional information:

0: No additional information available.

1: Axis type is not a PLC or command axis.

2: End position reached, motion completed.

3: Abort by NC RESET (key reset).

4: Moved out of monitoring window.

5: Torque reduction rejected by drive.

6: PLC has cancelled enables.

-    Interface signals are set.

-    Alarm display.

Note the supplementary conditions of the brake test, see additional info.

Clear alarm with the Delete key or NC START.


© Siemens AG 2005 All Rights Reserved