26003

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 parameterization error: lead screw pitch

%1 = Axis name, spindle number

The pitch of the ballscrew/trapezoidal leadscrew set in the axis-specific machine data 31030 LEADSCREW_PITCH is zero.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Determine the leadscrew pitch (specify the machine manufacturer or pitch measurement with spindle cover removed) and enter it in the machine data 31030: LEADSCREW_PITCH (mostly 10 or 5 mm/rev.).

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved


1-1144