26005

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 parameterization error: output rating

%1 = Axis name, spindle number

The output evaluation of the analog speed setpoint set in the machine data 32250 RATED_OUTVAL or in MD 32260 RATED_VELO is zero.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. The nominal output voltage in [%] of the maximum setpoint value (10 V) is entered in the machine data 32250 RATED_OUTVAL, at which the rated motor speed in [degrees/s] is to be reached (machine data 32260 RATED_VELO).

Clear alarm with the RESET key in all channels of this mode group. Restart part program.


© Siemens AG 2005 All Rights Reserved


1-1146